Mfg Part Number: VQ3483A | Manufacturer: Cornell Dubilier Electronics Corp | NSN : 5915-00-471-9955 |
NIIN : 004719955 | Item Name : filter radio freque | CAGE Code : 93790 |
FSC : 5915 Filters and Networks |
We are pleased to announce that the NSN Part VQ3483A is currently available for immediate purchase through Alpha NSN. This Filter Radio Freque part is manufactured by Cornell Dubilier Electronics Corp and is listed alongside the NSN 5915-00-471-9955. If you are interested in purchasing VQ3483A part by Cornell Dubilier Electronics Corp, or any other component listed on our website, you may begin the purchasing process with our Instant RFQ service. To begin, simply fill out the RFQ form provided on this page with as much information as possible and click submit. With dedicated account managers readily available for our customers, you will receive a personalized solution within 15 minutes of submission. If you are facing an AOG situation, don't hesitate to contact our team to learn about same-day shipping options on select in-stock items.
Alpha NSN is your number one choice for purchasing high-quality NSN part VQ3483A, whether they be 5915-00-471-9955 or others. Also, at Alpha NSN, we list every item alongside its respective CAGE Code, such as 93790, allowing customers to cross-reference identifiers as desired. Additionally, as the only independent distributor with a NO CHINA Sourcing policy, we guarantee that every order is fully traceable or comes directly from a trusted manufacturer like Cornell Dubilier Electronics Corp. Submit an RFQ today to learn why so many customers rely on Alpha NSN to fulfill all their operational requirements.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-471-9955 Item Description: Filter Radio Freque | 5915 | 004719955 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Vq3483a | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.000 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.870 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.000 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.140 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.500 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.000 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.750 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+2000.0 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.500 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -55.0/+95.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.9 MILLIVOLTS AC 1ST RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.9 MILLIVOLTS AC 2ND RADIO INTERFERENCE |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 TAB, SOLDER LUG INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 150.0 VOLTS AT SEA LEVEL |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
![]() |