Mfg Part Number: JA2S-A3-A-0005-03E | Alternate P/N: JA2SA3A000503E | Manufacturer: Lucent Technologies Inc |
NSN : 5925-01-398-1856 | NIIN : 013981856 | Item Name : circuit breaker |
CAGE Code : 06KW9 | FSC : 5925 Circuit Breakers |
We are pleased to announce that the NSN Part JA2S-A3-A-0005-03E is currently available for immediate purchase through Alpha NSN. This Circuit Breaker part is manufactured by Lucent Technologies Inc and is listed alongside the NSN 5925-01-398-1856. If you are interested in purchasing JA2S-A3-A-0005-03E part by Lucent Technologies Inc, or any other component listed on our website, you may begin the purchasing process with our Instant RFQ service. To begin, simply fill out the RFQ form provided on this page with as much information as possible and click submit. With dedicated account managers readily available for our customers, you will receive a personalized solution within 15 minutes of submission. If you are facing an AOG situation, don't hesitate to contact our team to learn about same-day shipping options on select in-stock items.
Alpha NSN is your number one choice for purchasing high-quality NSN part JA2S-A3-A-0005-03E, whether they be 5925-01-398-1856 or others. Also, at Alpha NSN, we list every item alongside its respective CAGE Code, such as 06KW9, allowing customers to cross-reference identifiers as desired. Additionally, as the only independent distributor with a NO CHINA Sourcing policy, we guarantee that every order is fully traceable or comes directly from a trusted manufacturer like Lucent Technologies Inc. Submit an RFQ today to learn why so many customers rely on Alpha NSN to fulfill all their operational requirements.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-398-1856 Item Description: Circuit Breaker | 5925 | 013981856 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ja2s-A3-A-0005-03e | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.680 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC ALL LOCATIONS |
AJEC | Boss Height | 0.150 INCHES NOMINAL |
AKPX | Pole Quantity | 2 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
ADAT | Body Width | 1.500 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
CPRT | Manual Actuator Type And Quantity | 2 TOGGLE |
THSD | Thread Series Designator | UNC |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 4 TAB, SOLDER LUG |
AJWX | Mounting Surface To Terminal End Distance | 2.285 INCHES NOMINAL |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 2.000 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.680 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 10.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 100.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
![]() |